Strong Wall (Seismic Load Reaction Wall)
NCDMM Lab

The system can apply pseudo-dynamic and quasi-static loads on the full-scale test specimen:
(a) Buildings up to three storeys (10m),
(b) Bridge piers up to 10m height,
(c) Other structures, components and assemblages.

  1.   Made of M45 Grade High Performance RCC
  2.   L-Shaped Wall with through 80mm diameter holes (With MS sleeves) at 600mm pitch
  3.   Structural floor footprint -19m x 9m
  4.   Slab Dimension - 25m x 12m
  5.   Electric overhead crane capacity - 20/5 Ton
  6.   Wall Height - 11m
  7.   Short Wall Thickness – 3m
  8.   Slab Thickness – 1m

LRB Base Isolation Testing Rig
NCDMM Lab

It can test Isolation devices and Bridge Bearings under biaxial loads

  1.   Vertical compression load capacity-12000 kN
  2.   Horizontal cyclic load capacity-3000 kN
  3.   Displacement Capacity- ±250mm

Servo Valve Actuators
NCDMM Lab

Currently NETF has 3 Servo Valve Actuators-
1. Dynamic Actuator-I

  1.   Capacity-1000kN
  2.   Stoke- ±250mm str
2. Dynamic Actuator-II
  1.   Capacity-500kN
  2.   Stoke- ±250mm str
3. Static Actuator-II
  1.   Capacity-1000kN
  2.   Stoke- 400mm str
These Actuators are powered by a 250 lpm hydraulic power supply.

Horizontal Harmonic Shake Table Setup
NCDMM Lab

Specifications

  1.   Oscilloscope
  2.   Accelerometers
  3.   Transducers Conditioner
  4.   Shake Table
  5.   Single Storey Shear Frame
  6.   Type - Cylindrical CAM
  7.   Capacity – 30kg
  8.   Amplitude-0.5, 1, 2 & 10mm

Seismic Wave Amplification and Vertical Shake Table
NCDMM Lab
Dynamic Vibration Absorber
NCDMM Lab
Electro Dynamic Vibration Test System
NCDMM Lab

Specifications

  1.   Displacement- 38mm
  2.   Maximum Payload- 150kg
  3.   Force Capacity- Sine = 600 kg(f)
    Random = 420 kg(f)
  4.   Frequency Range- 5-2000Hz

Horizontal Non-Harmonic Shake Table Setup
NCDMM Lab

Specifications

  1.   Oscilloscope
  2.   Accelerometers
  3.   Transducers Conditioner
  4.   Shake Table
  5.   Three Storey Shear Frame
  6.   Type - Cylindrical CAM
  7.   Capacity – 30kg
  8.   Amplitude-0.5, 1, 2 & 10mm

Different Arrangement for Tests
NCDMM Lab
NCDMM Lab
NCDMM Lab
NCDMM Lab
NCDMM Lab
NCDMM Lab

Computer & Structures, Inc.
  1.   Perform 3D
  2.   SAP2000
  3.   ETABS
Itasca Consulting Group, Inc.
  1.   UDEC
SIMULIA Abaqus Software
Bentley Academic SELECT
  1.   Bridge Analysis

OpenBridge Designer, LEAP Bridge Concrete, LEAP Bridge Steel, RM Bridge Advanced, RM Bridge Enterprise

  1.   Building Design

OpenBuildings Designer (enabled with Energy Simulator and GenerativeComponents capabilities), OpenBuildings Station Designer (includes LEGION Simulator and LEGION Model Builder)

  1.   Offshore Structural Analysis

MAXSURF Enterprise, On-campus use only: SACS Marine Enterprise, SACS Offshore Structure Enterprise, MOSES Advanced, MOSES Enterprise

  1.   Structural Analysis and Detailing

STAAD.Pro, STAAD Advanced Concrete Design, STAAD Foundation Advanced, RAM Structural System, RAM Connection, RAM Elements, RAM Concept, MicroStran, ProStructures

Matlab 2014a & Simulink